;Description##OTHER##;ø (mm)##OTHER##;H_Detector (mm)##OTHER##;H_Base (mm)##OTHER##;H_Total (mm)##OTHER##;Weight##OTHER##;Min_Wire Size##OTHER##;Max_Wire Size##OTHER##;Product Material##OTHER##;Voltage Allowed##OTHER##;Voltage Normal##OTHER##;Ambient Temperature Operating##OTHER##;Ambient Temperature Storage##OTHER##;Ambient Humidity##OTHER##;Ingress Protection Rating##OTHER##;Current Quiescent##OTHER##;Current Active Internal LED##OTHER##;Current Active External LED##OTHER##;Address Range##OTHER##;Short Circuit Isolator##OTHER##;Tested and Approved##OTHER##;CPR##OTHER##;Vds Approval##OTHER##;Model##OTHER##;Bases##OTHER##;Manufacturer##OTHER##;Type Comments##OTHER##;URL##OTHER##;Omniclass Code##OTHER##;Omniclass Description##OTHER##;Uniclass 2015 Code##OTHER##;Uniclass 2015 Description##OTHER##;Uniformat 2010 Code##OTHER##;Uniformat 2010 Description##OTHER##;Version##OTHER## 4400_3312;Analog multi (smoke and heat) detector 4400 with 3312 analog base;102;41;6;47;75g;Ø 0.6 mm (0.3 mm²);Ø 1.6 mm (2 mm²);Polycarbonate_Panasonic_Grey;12 – 30 VDC;24 VDC;-10 to +50 °C;-25 to +75 °C;Maximum 95 % RH ;IP41;0.3 mA ;1.3 mA;1.8 mA;1-253;No;EN54-7, EN54-5;0786-CPR-21172;G212106;4400;Bases : 3312;Panasonic;The analog multi detector 4400 consists of one photoelectric (optical) smoke detector and one heat detector within the low profile housing. Artificial Intelligence uses combined smoke and heat sensing for the fire judgement.;https://www.panasonic-fire-security.com;23.85.30.21.11.11.11;Smoke Detectors;Pr_75_80_30_27 ;Fire and smoke detector bases;D7050;Detection and Alarm;RVT20 4400W_3312W;Analog multi (smoke and heat) detector 4400W with 3312W analog base;102;41;6;47;75g;Ø 0.6 mm (0.3 mm²);Ø 1.6 mm (2 mm²);Polycarbonate_Panasonic_White;12 – 30 V DC;24V DC;-10 to +50 °C;-25 to +75 °C;Maximum 95 % RH ;IP41;0.3 mA ;1.3 mA;1.8 mA;1-253;No;EN54-7, EN54-5;0786-CPR-21172;G212106;4400W;Bases : 3312W;Panasonic;The analog multi detector 4400W consists of one photoelectric (optical) smoke detector and one heat detector within the low profile housing. Artificial Intelligence uses combined smoke and heat sensing for the fire judgement.;https://www.panasonic-fire-security.com;23.85.30.21.11.11.11;Smoke Detectors;Pr_75_80_30_27 ;Fire and smoke detector bases;D7050;Detection and Alarm;RVT20 4400_3312F;Analog multi (smoke and heat) detector 4400 with 3312F analog base;102;41;6;47;75g;Ø 0.6 mm (0.28 mm²);Ø 1.25 mm (1.2 mm²);Polycarbonate_Panasonic_Grey;12 – 30 V DC;24V DC;-10 to +50 °C;-25 to +75 °C;Maximum 95 % RH ;IP41;0.3 mA ;1.3 mA;1.8 mA;1-253;No;EN54-7, EN54-5;0786-CPR-21172;G212106;4400;Bases : 3312F;Panasonic;The analog multi detector 4400 consists of one photoelectric (optical) smoke detector and one heat detector within the low profile housing. Artificial Intelligence uses combined smoke and heat sensing for the fire judgement.;https://www.panasonic-fire-security.com;23.85.30.21.11.11.11;Smoke Detectors;Pr_75_80_30_27 ;Fire and smoke detector bases;D7050;Detection and Alarm;RVT20 4400W_3312FW;Analog multi (smoke and heat) detector 4400W with 3312FW analog base;102;41;6;47;75g;Ø 0.6 mm (0.28 mm²);Ø 1.25 mm (1.2 mm²);Polycarbonate_Panasonic_White;12 – 30 V DC;24V DC;-10 to +50 °C;-25 to +75 °C;Maximum 95 % RH ;IP41;0.3 mA ;1.3 mA;1.8 mA;1-253;No;EN54-7, EN54-5;0786-CPR-21172;G212106;4400W;Bases : 3312FW;Panasonic;The analog multi detector 4400W consists of one photoelectric (optical) smoke detector and one heat detector within the low profile housing. Artificial Intelligence uses combined smoke and heat sensing for the fire judgement.;https://www.panasonic-fire-security.com;23.85.30.21.11.11.11;Smoke Detectors;Pr_75_80_30_27 ;Fire and smoke detector bases;D7050;Detection and Alarm;RVT20 4400_3312FL;Analog multi (smoke and heat) detector 4400 with 3312FL analog base;102;41;6;47;75g;Ø 0.6 mm (0.28 mm²);Ø 1.25 mm (1.2 mm²);Polycarbonate_Panasonic_Grey;12 – 30 V DC;24V DC;-10 to +50 °C;-25 to +75 °C;Maximum 95 % RH ;IP41;0.3 mA ;1.3 mA;1.8 mA;1-253;No;EN54-7, EN54-5;0786-CPR-21172;G212106;4400;Bases : 3312FL;Panasonic;The analog multi detector 4400 consists of one photoelectric (optical) smoke detector and one heat detector within the low profile housing. Artificial Intelligence uses combined smoke and heat sensing for the fire judgement.;https://www.panasonic-fire-security.com;23.85.30.21.11.11.11;Smoke Detectors;Pr_75_80_30_27 ;Fire and smoke detector bases;D7050;Detection and Alarm;RVT20 4400W_3312FLW;Analog multi (smoke and heat) detector 4400W with 3312FLW analog base;102;41;6;47;75g;Ø 0.6 mm (0.28 mm²);Ø 1.25 mm (1.2 mm²);Polycarbonate_Panasonic_White;12 – 30 V DC;24V DC;-10 to +50 °C;-25 to +75 °C;Maximum 95 % RH ;IP41;0.3 mA ;1.3 mA;1.8 mA;1-253;No;EN54-7, EN54-5;0786-CPR-21172;G212106;4400W;Bases : 3312FLW;Panasonic;The analog multi detector 4400W consists of one photoelectric (optical) smoke detector and one heat detector within the low profile housing. Artificial Intelligence uses combined smoke and heat sensing for the fire judgement.;https://www.panasonic-fire-security.com;23.85.30.21.11.11.11;Smoke Detectors;Pr_75_80_30_27 ;Fire and smoke detector bases;D7050;Detection and Alarm;RVT20 4400_3379;Analog multi (smoke and heat) detector 4400 with 3379 addressable sound base;102;41;6;47;75g;Ø 0.6 mm (0.3 mm²);Ø 1.6 mm (2 mm²);Polycarbonate_Panasonic_Grey;12 – 30 V DC;24V DC;-10 to +50 °C;-25 to +75 °C;Maximum 95 % RH ;IP41;0.3 mA ;1.3 mA;1.8 mA;1-253;No;EN54-7, EN54-5, EN54-3 (siren base);0786-CPR-21172;G212106;4400;Bases : 3379;Panasonic;The analog multi detector 4400 consists of one photoelectric (optical) smoke detector and one heat detector within the low profile housing. Artificial Intelligence uses combined smoke and heat sensing for the fire judgement.;https://www.panasonic-fire-security.com;23.85.30.21.11.11.11;Smoke Detectors;Pr_75_80_30_27 ;Fire and smoke detector bases;D7050;Detection and Alarm;RVT20 4400W_3379W;Analog multi (smoke and heat) detector 4400W with 3379W addressable sound base;102;41;6;47;75g;Ø 0.6 mm (0.3 mm²);Ø 1.6 mm (2 mm²);Polycarbonate_Panasonic_White;12 – 30 V DC;24V DC;-10 to +50 °C;-25 to +75 °C;Maximum 95 % RH ;IP41;0.3 mA ;1.3 mA;1.8 mA;1-253;No;EN54-7, EN54-5, EN54-3 (siren base);0786-CPR-21172;G212106;4400W;Bases : 3379W;Panasonic;The analog multi detector 4400W consists of one photoelectric (optical) smoke detector and one heat detector within the low profile housing. Artificial Intelligence uses combined smoke and heat sensing for the fire judgement.;https://www.panasonic-fire-security.com;23.85.30.21.11.11.11;Smoke Detectors;Pr_75_80_30_27 ;Fire and smoke detector bases;D7050;Detection and Alarm;RVT20 4400_4313;Analog multi (smoke and heat) detector 4400 with 4313 analog base with isolator;102;41;6;47;75g;Ø 0.6 mm (0.3 mm²);Ø 1.6 mm (2 mm²);Polycarbonate_Panasonic_Grey;12 – 30 V DC;24V DC;-10 to +50 °C;-25 to +75 °C;Maximum 95 % RH ;IP41;0.3 mA ;1.3 mA;1.8 mA;1-253;Yes (base);EN54-7, EN54-5, EN54-17 (isolator base);0786-CPR-21172;G212106;4400;Bases : 4313;Panasonic;The analog multi detector 4400 consists of one photoelectric (optical) smoke detector and one heat detector within the low profile housing. Artificial Intelligence uses combined smoke and heat sensing for the fire judgement.;https://www.panasonic-fire-security.com;23.85.30.21.11.11.11;Smoke Detectors;Pr_75_80_30_27 ;Fire and smoke detector bases;D7050;Detection and Alarm;RVT20 4400W_4313W;Analog multi (smoke and heat) detector 4400W with 4313W analog base with isolator;102;41;6;47;75g;Ø 0.6 mm (0.3 mm²);Ø 1.6 mm (2 mm²);Polycarbonate_Panasonic_White;12 – 30 V DC;24V DC;-10 to +50 °C;-25 to +75 °C;Maximum 95 % RH ;IP41;0.3 mA ;1.3 mA;1.8 mA;1-253;Yes (base);EN54-7, EN54-5, EN54-17 (isolator base);0786-CPR-21172;G212106;4400W;Bases : 4313W;Panasonic;The analog multi detector 4400W consists of one photoelectric (optical) smoke detector and one heat detector within the low profile housing. Artificial Intelligence uses combined smoke and heat sensing for the fire judgement.;https://www.panasonic-fire-security.com;23.85.30.21.11.11.11;Smoke Detectors;Pr_75_80_30_27 ;Fire and smoke detector bases;D7050;Detection and Alarm;RVT20