;Description##OTHER##;ø (mm)##OTHER##;H_Detector (mm)##OTHER##;H_Base (mm)##OTHER##;H_Total (mm)##OTHER##;Weight##OTHER##;Min_Wire Size##OTHER##;Max_Wire Size##OTHER##;Product Material##OTHER##;Voltage Allowed##OTHER##;Voltage Normal##OTHER##;Ambient Temperature Operating##OTHER##;Ambient Temperature Storage##OTHER##;Ambient Humidity##OTHER##;Ingress Protection Rating##OTHER##;Current Quiescent##OTHER##;Current Active Internal LED##OTHER##;Current Active External LED##OTHER##;Address Range##OTHER##;Short Circuit Isolator##OTHER##;Tested and Approved##OTHER##;CPR##OTHER##;Vds Approval##OTHER##;Model##OTHER##;Bases##OTHER##;Manufacturer##OTHER##;Type Comments##OTHER##;URL##OTHER##;Omniclass Code##OTHER##;Omniclass Description##OTHER##;Uniclass 2015 Code##OTHER##;Uniclass 2015 Description##OTHER##;Uniformat 2010 Code##OTHER##;Uniformat 2010 Description##OTHER##;Version##OTHER## 4401_3312;Analog photoelectric smoke detector 4401 with 3312 analog base;102;34;6;40;75g;Ø 0.6 mm (0.3 mm²);Ø 1.6 mm (2 mm²);Polycarbonate_Panasonic_Grey;12 – 30 VDC;24 VDC;-10 to +50 °C;-25 to +75 °C;Maximum 95 % RH ;IP41;0.3 mA ;1.3 mA;1.8 mA;1-253;No;EN54-7;0786-CPR-21175;G212107;4401;Bases : 3312;Panasonic;The photoelectric smoke detector 4401 has low profile housing. Artificial Intelligence uses smoke sensing for the fire judgement, as well as variable sensitivity and time delay based on the smoke changes just before the alarm level is reached.;https://www.panasonic-fire-security.com;23.85.30.21.11.11.11;Smoke Detectors;Pr_75_80_30_27 ;Fire and smoke detector bases;D7050;Detection and Alarm;RVT20 4401W_3312W;Analog photoelectric smoke detector 4401W with 3312W analog base;102;34;6;40;75g;Ø 0.6 mm (0.3 mm²);Ø 1.6 mm (2 mm²);Polycarbonate_Panasonic_White;12 – 30 VDC;24 VDC;-10 to +50 °C;-25 to +75 °C;Maximum 95 % RH ;IP41;0.3 mA ;1.3 mA;1.8 mA;1-253;No;EN54-7;0786-CPR-21175;G212107;4401W;Bases : 3312W;Panasonic;The photoelectric smoke detector 4401W has low profile housing. Artificial Intelligence uses smoke sensing for the fire judgement, as well as variable sensitivity and time delay based on the smoke changes just before the alarm level is reached.;https://www.panasonic-fire-security.com;23.85.30.21.11.11.11;Smoke Detectors;Pr_75_80_30_27 ;Fire and smoke detector bases;D7050;Detection and Alarm;RVT20 4401_3312F;Analog photoelectric smoke detector 4401 with 3312F analog base;102;34;6;40;75g;Ø 0.6 mm (0.28 mm²);Ø 1.25 mm (1.2 mm²);Polycarbonate_Panasonic_Grey;12 – 30 VDC;24 VDC;-10 to +50 °C;-25 to +75 °C;Maximum 95 % RH ;IP41;0.3 mA ;1.3 mA;1.8 mA;1-253;No;EN54-7;0786-CPR-21175;G212107;4401;Bases : 3312F;Panasonic;The photoelectric smoke detector 4401 has low profile housing. Artificial Intelligence uses smoke sensing for the fire judgement, as well as variable sensitivity and time delay based on the smoke changes just before the alarm level is reached.;https://www.panasonic-fire-security.com;23.85.30.21.11.11.11;Smoke Detectors;Pr_75_80_30_27 ;Fire and smoke detector bases;D7050;Detection and Alarm;RVT20 4401W_3312FW;Analog photoelectric smoke detector 4401W with 3312FW analog base;102;34;6;40;75g;Ø 0.6 mm (0.28 mm²);Ø 1.25 mm (1.2 mm²);Polycarbonate_Panasonic_White;12 – 30 VDC;24 VDC;-10 to +50 °C;-25 to +75 °C;Maximum 95 % RH ;IP41;0.3 mA ;1.3 mA;1.8 mA;1-253;No;EN54-7;0786-CPR-21175;G212107;4401W;Bases : 3312FW;Panasonic;The photoelectric smoke detector 4401W has low profile housing. Artificial Intelligence uses smoke sensing for the fire judgement, as well as variable sensitivity and time delay based on the smoke changes just before the alarm level is reached.;https://www.panasonic-fire-security.com;23.85.30.21.11.11.11;Smoke Detectors;Pr_75_80_30_27 ;Fire and smoke detector bases;D7050;Detection and Alarm;RVT20 4401_3312FL;Analog photoelectric smoke detector 4401 with 3312FL analog base;102;34;6;40;75g;Ø 0.6 mm (0.28 mm²);Ø 1.25 mm (1.2 mm²);Polycarbonate_Panasonic_Grey;12 – 30 VDC;24 VDC;-10 to +50 °C;-25 to +75 °C;Maximum 95 % RH ;IP41;0.3 mA ;1.3 mA;1.8 mA;1-253;No;EN54-7;0786-CPR-21175;G212107;4401;Bases : 3312FL;Panasonic;The photoelectric smoke detector 4401 has low profile housing. Artificial Intelligence uses smoke sensing for the fire judgement, as well as variable sensitivity and time delay based on the smoke changes just before the alarm level is reached.;https://www.panasonic-fire-security.com;23.85.30.21.11.11.11;Smoke Detectors;Pr_75_80_30_27 ;Fire and smoke detector bases;D7050;Detection and Alarm;RVT20 4401W_3312FLW;Analog photoelectric smoke detector 4401W with 3312FLW analog base;102;34;6;40;75g;Ø 0.6 mm (0.28 mm²);Ø 1.25 mm (1.2 mm²);Polycarbonate_Panasonic_White;12 – 30 VDC;24 VDC;-10 to +50 °C;-25 to +75 °C;Maximum 95 % RH ;IP41;0.3 mA ;1.3 mA;1.8 mA;1-253;No;EN54-7;0786-CPR-21175;G212107;4401W;Bases : 3312FLW;Panasonic;The photoelectric smoke detector 4401W has low profile housing. Artificial Intelligence uses smoke sensing for the fire judgement, as well as variable sensitivity and time delay based on the smoke changes just before the alarm level is reached.;https://www.panasonic-fire-security.com;23.85.30.21.11.11.11;Smoke Detectors;Pr_75_80_30_27 ;Fire and smoke detector bases;D7050;Detection and Alarm;RVT20 4401_3379;Analog photoelectric smoke detector 4401 with 3379 addressable sound base;102;34;6;40;75g;Ø 0.6 mm (0.3 mm²);Ø 1.6 mm (2 mm²);Polycarbonate_Panasonic_Grey;12 – 30 VDC;24 VDC;-10 to +50 °C;-25 to +75 °C;Maximum 95 % RH ;IP41;0.3 mA ;1.3 mA;1.8 mA;1-253;No;EN54-7, EN54-3 (siren base);0786-CPR-21175;G212107;4401;Bases : 3379;Panasonic;The photoelectric smoke detector 4401 has low profile housing. Artificial Intelligence uses smoke sensing for the fire judgement, as well as variable sensitivity and time delay based on the smoke changes just before the alarm level is reached.;https://www.panasonic-fire-security.com;23.85.30.21.11.11.11;Smoke Detectors;Pr_75_80_30_27 ;Fire and smoke detector bases;D7050;Detection and Alarm;RVT20 4401W_3379W;Analog photoelectric smoke detector 4401W with 3379W addressable sound base;102;34;6;40;75g;Ø 0.6 mm (0.3 mm²);Ø 1.6 mm (2 mm²);Polycarbonate_Panasonic_White;12 – 30 VDC;24 VDC;-10 to +50 °C;-25 to +75 °C;Maximum 95 % RH ;IP41;0.3 mA ;1.3 mA;1.8 mA;1-253;No;EN54-7, EN54-3 (siren base);0786-CPR-21175;G212107;4401W;Bases : 3379W;Panasonic;The photoelectric smoke detector 4401W has low profile housing. Artificial Intelligence uses smoke sensing for the fire judgement, as well as variable sensitivity and time delay based on the smoke changes just before the alarm level is reached.;https://www.panasonic-fire-security.com;23.85.30.21.11.11.11;Smoke Detectors;Pr_75_80_30_27 ;Fire and smoke detector bases;D7050;Detection and Alarm;RVT20 4401_4313;Analog photoelectric smoke detector 4401 with 4313 analog base with isolator;102;34;6;40;75g;Ø 0.6 mm (0.3 mm²);Ø 1.6 mm (2 mm²);Polycarbonate_Panasonic_Grey;12 – 30 VDC;24 VDC;-10 to +50 °C;-25 to +75 °C;Maximum 95 % RH ;IP41;0.3 mA ;1.3 mA;1.8 mA;1-253;Yes (base);EN54-7, EN54-17 (isolator base);0786-CPR-21175;G212107;4401;Bases : 4313;Panasonic;The photoelectric smoke detector 4401 has low profile housing. Artificial Intelligence uses smoke sensing for the fire judgement, as well as variable sensitivity and time delay based on the smoke changes just before the alarm level is reached.;https://www.panasonic-fire-security.com;23.85.30.21.11.11.11;Smoke Detectors;Pr_75_80_30_27 ;Fire and smoke detector bases;D7050;Detection and Alarm;RVT20 4401W_4313W;Analog photoelectric smoke detector 4401W with 4313W analog base with isolator;102;34;6;40;75g;Ø 0.6 mm (0.3 mm²);Ø 1.6 mm (2 mm²);Polycarbonate_Panasonic_White;12 – 30 VDC;24 VDC;-10 to +50 °C;-25 to +75 °C;Maximum 95 % RH ;IP41;0.3 mA ;1.3 mA;1.8 mA;1-253;Yes (base);EN54-7, EN54-17 (isolator base);0786-CPR-21175;G212107;4401W;Bases : 4313W;Panasonic;The photoelectric smoke detector 4401W has low profile housing. Artificial Intelligence uses smoke sensing for the fire judgement, as well as variable sensitivity and time delay based on the smoke changes just before the alarm level is reached.;https://www.panasonic-fire-security.com;23.85.30.21.11.11.11;Smoke Detectors;Pr_75_80_30_27 ;Fire and smoke detector bases;D7050;Detection and Alarm;RVT20