;Description##OTHER##;ø (mm)##OTHER##;H_Detector (mm)##OTHER##;H_Base (mm)##OTHER##;H_Total (mm)##OTHER##;Weight##OTHER##;Min_Wire Size##OTHER##;Max_Wire Size##OTHER##;Product Material##OTHER##;Voltage Allowed##OTHER##;Voltage Normal##OTHER##;Ambient Temperature Operating##OTHER##;Ambient Temperature Storage##OTHER##;Ambient Humidity##OTHER##;Ingress Protection Rating##OTHER##;Current Quiescent##OTHER##;Current Active Internal LED##OTHER##;Current Active External LED##OTHER##;Address Range##OTHER##;Short Circuit Isolator##OTHER##;Tested and Approved##OTHER##;Model##OTHER##;Bases##OTHER##;Manufacturer##OTHER##;Type Comments##OTHER##;URL##OTHER##;Omniclass Code##OTHER##;Omniclass Description##OTHER##;Uniclass 2015 Code##OTHER##;Uniclass 2015 Description##OTHER##;Uniformat 2010 Code##OTHER##;Uniformat 2010 Description##OTHER##;Version##OTHER## 4402_3312;Analog multi detector with CO 4402 with 3312 analog base;102;63;6;69;131g;Ø 0.6 mm (0.3 mm²);Ø 1.6 mm (2 mm²);Polycarbonate_Panasonic_Grey;12 – 30 VDC;24 VDC;-10 to +50 °C;-25 to +75 °C;Maximum 95 % RH ;IP41;0.3 mA ;1.3 mA;1.8 mA;1-253;No;Complies with EN54-31;4402;Bases : 3312;Panasonic;The analog multi detector with CO consists of one photoelectric (optical) smoke detector, one heat detector and one CO sensor within the low profile housing. The heat sensing element is a thermistor and the CO sensor is of chemical type. Artificial Intelligence uses combined smoke and heat sensing for the fire judgement, as well as smoke + CO. This will secure real fire alarms and minimize the not wanted nuisance alarms.;https://www.panasonic-fire-security.com;23.85.30.21.11.11.11;Smoke Detectors;Pr_75_80_30_27 ;Fire and smoke detector bases;D7050;Detection and Alarm;RVT20 4402_3312F;Analog multi detector with CO 4402 with 3312F analog base;102;63;6;69;131g;Ø 0.6 mm (0.28 mm²);Ø 1.25 mm (1.2 mm²);Polycarbonate_Panasonic_Grey;12 – 30 VDC;24 VDC;-10 to +50 °C;-25 to +75 °C;Maximum 95 % RH ;IP41;0.3 mA ;1.3 mA;1.8 mA;1-253;No;Complies with EN54-31;4402;Bases : 3312F;Panasonic;The analog multi detector with CO consists of one photoelectric (optical) smoke detector, one heat detector and one CO sensor within the low profile housing. The heat sensing element is a thermistor and the CO sensor is of chemical type. Artificial Intelligence uses combined smoke and heat sensing for the fire judgement, as well as smoke + CO. This will secure real fire alarms and minimize the not wanted nuisance alarms.;https://www.panasonic-fire-security.com;23.85.30.21.11.11.11;Smoke Detectors;Pr_75_80_30_27 ;Fire and smoke detector bases;D7050;Detection and Alarm;RVT20 4402_3312FL;Analog multi detector with CO 4402 with 3312FL analog base;102;63;6;69;131g;Ø 0.6 mm (0.28 mm²);Ø 1.25 mm (1.2 mm²);Polycarbonate_Panasonic_Grey;12 – 30 VDC;24 VDC;-10 to +50 °C;-25 to +75 °C;Maximum 95 % RH ;IP41;0.3 mA ;1.3 mA;1.8 mA;1-253;No;Complies with EN54-31;4402;Bases : 3312FL;Panasonic;The analog multi detector with CO consists of one photoelectric (optical) smoke detector, one heat detector and one CO sensor within the low profile housing. The heat sensing element is a thermistor and the CO sensor is of chemical type. Artificial Intelligence uses combined smoke and heat sensing for the fire judgement, as well as smoke + CO. This will secure real fire alarms and minimize the not wanted nuisance alarms.;https://www.panasonic-fire-security.com;23.85.30.21.11.11.11;Smoke Detectors;Pr_75_80_30_27 ;Fire and smoke detector bases;D7050;Detection and Alarm;RVT20 4402_3379;Analog multi detector with CO 4402 with 3379 addressable sound base;102;63;6;69;131g;Ø 0.6 mm (0.3 mm²);Ø 1.6 mm (2 mm²);Polycarbonate_Panasonic_Grey;12 – 30 VDC;24 VDC;-10 to +50 °C;-25 to +75 °C;Maximum 95 % RH ;IP41;0.3 mA ;1.3 mA;1.8 mA;1-253;No;Complies with EN54-31, EN54-3 (siren base);4402;Bases : 3379;Panasonic;The analog multi detector with CO consists of one photoelectric (optical) smoke detector, one heat detector and one CO sensor within the low profile housing. The heat sensing element is a thermistor and the CO sensor is of chemical type. Artificial Intelligence uses combined smoke and heat sensing for the fire judgement, as well as smoke + CO. This will secure real fire alarms and minimize the not wanted nuisance alarms.;https://www.panasonic-fire-security.com;23.85.30.21.11.11.11;Smoke Detectors;Pr_75_80_30_27 ;Fire and smoke detector bases;D7050;Detection and Alarm;RVT20 4402_4313;Analog multi detector with CO 4402 with 4313 analog base with isolator;102;63;6;69;131g;Ø 0.6 mm (0.3 mm²);Ø 1.6 mm (2 mm²);Polycarbonate_Panasonic_Grey;12 – 30 VDC;24 VDC;-10 to +50 °C;-25 to +75 °C;Maximum 95 % RH ;IP41;0.3 mA ;1.3 mA;1.8 mA;1-253;Yes (base);Complies with EN54-31, EN54-17 (isolator base);4402;Bases : 4313;Panasonic;The analog multi detector with CO consists of one photoelectric (optical) smoke detector, one heat detector and one CO sensor within the low profile housing. The heat sensing element is a thermistor and the CO sensor is of chemical type. Artificial Intelligence uses combined smoke and heat sensing for the fire judgement, as well as smoke + CO. This will secure real fire alarms and minimize the not wanted nuisance alarms.;https://www.panasonic-fire-security.com;23.85.30.21.11.11.11;Smoke Detectors;Pr_75_80_30_27 ;Fire and smoke detector bases;D7050;Detection and Alarm;RVT20