;Description##OTHER##;ø (mm)##OTHER##;H_Detector (mm)##OTHER##;H_Base (mm)##OTHER##;H_Total (mm)##OTHER##;Weight##OTHER##;Min_Wire Size##OTHER##;Max_Wire Size##OTHER##;Product Material##OTHER##;Voltage Allowed##OTHER##;Voltage Normal##OTHER##;Ambient Temperature Operating##OTHER##;Ambient Temperature Storage##OTHER##;Ambient Humidity##OTHER##;Ingress Protection Rating##OTHER##;Current Quiescent##OTHER##;Current Active Internal LED##OTHER##;Current Active External LED##OTHER##;Address Range##OTHER##;Short Circuit Isolator##OTHER##;Tested and Approved##OTHER##;CPR##OTHER##;Vds Approval##OTHER##;Model##OTHER##;Bases##OTHER##;Manufacturer##OTHER##;Type Comments##OTHER##;URL##OTHER##;Omniclass Code##OTHER##;Omniclass Description##OTHER##;Uniclass 2015 Code##OTHER##;Uniclass 2015 Description##OTHER##;Uniformat 2010 Code##OTHER##;Uniformat 2010 Description##OTHER##;Version##OTHER## 4408_3312;Analog heat detector 4408 with 3312 analog base;102;36;6;42;51g;Ø 0.6 mm (0.3 mm²);Ø 1.6 mm (2 mm²);FR ABS and polycarbonate_Panasonic_Grey;12 – 30 VDC;24 VDC;"A1: -20 / +25 / +50°C A2 S: -20 / +25 / +50°C B S: -20 / +40 / +65 °C";-25 to +70 °C;Maximum 95 % RH ;IP51;0.3 mA ;2.3 mA;4.3 mA;1-253;No;EN54-5;0786-CPR-21204;G208109;4408;Bases : 3312;Panasonic;The analog heat detector 4408 measures the temperature through a thermistor. The temperature range is 0°C to 100°C in steps of 0.5?C. Algorithms for category A1, A2 S, and B S are used for detectors in NORMAL mode. The algorithm is programmed via EBLWin.;https://www.panasonic-fire-security.com;23.85.30.21.11.11.11;Smoke Detectors;Pr_75_80_30_27 ;Fire and smoke detector bases;D7050;Detection and Alarm;RVT20 4408W_3312W;Analog heat detector 4408W with 3312W analog base;102;36;6;42;51g;Ø 0.6 mm (0.3 mm²);Ø 1.6 mm (2 mm²);FR ABS and polycarbonate_Panasonic_White;12 – 30 VDC;24 VDC;"A1: -20 / +25 / +50°C A2 S: -20 / +25 / +50°C B S: -20 / +40 / +65 °C";-25 to +70 °C;Maximum 95 % RH ;IP51;0.3 mA ;2.3 mA;4.3 mA;1-253;No;EN54-5;0786-CPR-21204;G208109;4408W;Bases : 3312W;Panasonic;The analog heat detector 4408 measures the temperature through a thermistor. The temperature range is 0°C to 100°C in steps of 0.5?C. Algorithms for category A1, A2 S, and B S are used for detectors in NORMAL mode. The algorithm is programmed via EBLWin.;https://www.panasonic-fire-security.com;23.85.30.21.11.11.11;Smoke Detectors;Pr_75_80_30_27 ;Fire and smoke detector bases;D7050;Detection and Alarm;RVT20 4408_3312F;Analog heat detector 4408 with 3312F analog base;102;36;6;42;51g;Ø 0.6 mm (0.28 mm²);Ø 1.25 mm (1.2 mm²);FR ABS and polycarbonate_Panasonic_Grey;12 – 30 VDC;24 VDC;"A1: -20 / +25 / +50°C A2 S: -20 / +25 / +50°C B S: -20 / +40 / +65 °C";-25 to +70 °C;Maximum 95 % RH ;IP51;0.3 mA ;2.3 mA;4.3 mA;1-253;No;EN54-5;0786-CPR-21204;G208109;4408;Bases : 3312F;Panasonic;The analog heat detector 4408 measures the temperature through a thermistor. The temperature range is 0°C to 100°C in steps of 0.5?C. Algorithms for category A1, A2 S, and B S are used for detectors in NORMAL mode. The algorithm is programmed via EBLWin.;https://www.panasonic-fire-security.com;23.85.30.21.11.11.11;Smoke Detectors;Pr_75_80_30_27 ;Fire and smoke detector bases;D7050;Detection and Alarm;RVT20 4408W_3312FW;Analog heat detector 4408W with 3312FW analog base;102;36;6;42;51g;Ø 0.6 mm (0.28 mm²);Ø 1.25 mm (1.2 mm²);FR ABS and polycarbonate_Panasonic_White;12 – 30 VDC;24 VDC;"A1: -20 / +25 / +50°C A2 S: -20 / +25 / +50°C B S: -20 / +40 / +65 °C";-25 to +70 °C;Maximum 95 % RH ;IP51;0.3 mA ;2.3 mA;4.3 mA;1-253;No;EN54-5;0786-CPR-21204;G208109;4408W;Bases : 3312FW;Panasonic;The analog heat detector 4408 measures the temperature through a thermistor. The temperature range is 0°C to 100°C in steps of 0.5?C. Algorithms for category A1, A2 S, and B S are used for detectors in NORMAL mode. The algorithm is programmed via EBLWin.;https://www.panasonic-fire-security.com;23.85.30.21.11.11.11;Smoke Detectors;Pr_75_80_30_27 ;Fire and smoke detector bases;D7050;Detection and Alarm;RVT20 4408_3312FL;Analog heat detector 4408 with 3312FL analog base;102;36;6;42;51g;Ø 0.6 mm (0.28 mm²);Ø 1.25 mm (1.2 mm²);FR ABS and polycarbonate_Panasonic_Grey;12 – 30 VDC;24 VDC;"A1: -20 / +25 / +50°C A2 S: -20 / +25 / +50°C B S: -20 / +40 / +65 °C";-25 to +70 °C;Maximum 95 % RH ;IP51;0.3 mA ;2.3 mA;4.3 mA;1-253;No;EN54-5;0786-CPR-21204;G208109;4408;Bases : 3312FL;Panasonic;The analog heat detector 4408 measures the temperature through a thermistor. The temperature range is 0°C to 100°C in steps of 0.5?C. Algorithms for category A1, A2 S, and B S are used for detectors in NORMAL mode. The algorithm is programmed via EBLWin.;https://www.panasonic-fire-security.com;23.85.30.21.11.11.11;Smoke Detectors;Pr_75_80_30_27 ;Fire and smoke detector bases;D7050;Detection and Alarm;RVT20 4408W_3312FLW;Analog heat detector 4408W with 3312FLW analog base;102;36;6;42;51g;Ø 0.6 mm (0.28 mm²);Ø 1.25 mm (1.2 mm²);FR ABS and polycarbonate_Panasonic_White;12 – 30 VDC;24 VDC;"A1: -20 / +25 / +50°C A2 S: -20 / +25 / +50°C B S: -20 / +40 / +65 °C";-25 to +70 °C;Maximum 95 % RH ;IP51;0.3 mA ;2.3 mA;4.3 mA;1-253;No;EN54-5;0786-CPR-21204;G208109;4408W;Bases : 3312FLW;Panasonic;The analog heat detector 4408 measures the temperature through a thermistor. The temperature range is 0°C to 100°C in steps of 0.5?C. Algorithms for category A1, A2 S, and B S are used for detectors in NORMAL mode. The algorithm is programmed via EBLWin.;https://www.panasonic-fire-security.com;23.85.30.21.11.11.11;Smoke Detectors;Pr_75_80_30_27 ;Fire and smoke detector bases;D7050;Detection and Alarm;RVT20 4408_3379;Analog heat detector 4408 with 3379 addressable sound base;102;36;6;42;51g;Ø 0.6 mm (0.3 mm²);Ø 1.6 mm (2 mm²);FR ABS and polycarbonate_Panasonic_Grey;12 – 30 VDC;24 VDC;"A1: -20 / +25 / +50°C A2 S: -20 / +25 / +50°C B S: -20 / +40 / +65 °C";-25 to +70 °C;Maximum 95 % RH ;IP51;0.3 mA ;2.3 mA;4.3 mA;1-253;No;EN54-5, EN54-3 (siren base);0786-CPR-21204;G208109;4408;Bases : 3379;Panasonic;The analog heat detector 4408 measures the temperature through a thermistor. The temperature range is 0°C to 100°C in steps of 0.5?C. Algorithms for category A1, A2 S, and B S are used for detectors in NORMAL mode. The algorithm is programmed via EBLWin.;https://www.panasonic-fire-security.com;23.85.30.21.11.11.11;Smoke Detectors;Pr_75_80_30_27 ;Fire and smoke detector bases;D7050;Detection and Alarm;RVT20 4408W_3379W;Analog heat detector 4408W with 3379W addressable sound base;102;36;6;42;51g;Ø 0.6 mm (0.3 mm²);Ø 1.6 mm (2 mm²);FR ABS and polycarbonate_Panasonic_White;12 – 30 VDC;24 VDC;"A1: -20 / +25 / +50°C A2 S: -20 / +25 / +50°C B S: -20 / +40 / +65 °C";-25 to +70 °C;Maximum 95 % RH ;IP51;0.3 mA ;2.3 mA;4.3 mA;1-253;No;EN54-5, EN54-3 (siren base);0786-CPR-21204;G208109;4408W;Bases : 3379W;Panasonic;The analog heat detector 4408 measures the temperature through a thermistor. The temperature range is 0°C to 100°C in steps of 0.5?C. Algorithms for category A1, A2 S, and B S are used for detectors in NORMAL mode. The algorithm is programmed via EBLWin.;https://www.panasonic-fire-security.com;23.85.30.21.11.11.11;Smoke Detectors;Pr_75_80_30_27 ;Fire and smoke detector bases;D7050;Detection and Alarm;RVT20 4408_4313;Analog heat detector 4408 with 4313 analog base with isolator;102;36;6;42;51g;Ø 0.6 mm (0.3 mm²);Ø 1.6 mm (2 mm²);FR ABS and polycarbonate_Panasonic_Grey;12 – 30 VDC;24 VDC;"A1: -20 / +25 / +50°C A2 S: -20 / +25 / +50°C B S: -20 / +40 / +65 °C";-25 to +70 °C;Maximum 95 % RH ;IP51;0.3 mA ;2.3 mA;4.3 mA;1-253;Yes (base);EN54-5, EN54-17 (isolator base);0786-CPR-21204;G208109;4408;Bases : 4313;Panasonic;The analog heat detector 4408 measures the temperature through a thermistor. The temperature range is 0°C to 100°C in steps of 0.5?C. Algorithms for category A1, A2 S, and B S are used for detectors in NORMAL mode. The algorithm is programmed via EBLWin.;https://www.panasonic-fire-security.com;23.85.30.21.11.11.11;Smoke Detectors;Pr_75_80_30_27 ;Fire and smoke detector bases;D7050;Detection and Alarm;RVT20 4408W_4313W;Analog heat detector 4408W with 4313W analog base with isolator;102;36;6;42;51g;Ø 0.6 mm (0.3 mm²);Ø 1.6 mm (2 mm²);FR ABS and polycarbonate_Panasonic_White;12 – 30 VDC;24 VDC;"A1: -20 / +25 / +50°C A2 S: -20 / +25 / +50°C B S: -20 / +40 / +65 °C";-25 to +70 °C;Maximum 95 % RH ;IP51;0.3 mA ;2.3 mA;4.3 mA;1-253;Yes (base);EN54-5, EN54-17 (isolator base);0786-CPR-21204;G208109;4408W;Bases : 4313W;Panasonic;The analog heat detector 4408 measures the temperature through a thermistor. The temperature range is 0°C to 100°C in steps of 0.5?C. Algorithms for category A1, A2 S, and B S are used for detectors in NORMAL mode. The algorithm is programmed via EBLWin.;https://www.panasonic-fire-security.com;23.85.30.21.11.11.11;Smoke Detectors;Pr_75_80_30_27 ;Fire and smoke detector bases;D7050;Detection and Alarm;RVT20