;Description##OTHER##;ø (mm)##OTHER##;Height (mm)##OTHER##;Weight##OTHER##;Min_Wire Size##OTHER##;Max_Wire Size##OTHER##;Product Material##OTHER##;Voltage Allowed##OTHER##;Voltage Normal##OTHER##;Ambient Temperature Operating##OTHER##;Ambient Temperature Storage##OTHER##;Ambient Humidity##OTHER##;Ingress Protection Rating##OTHER##;Current Quiescent##OTHER##;Current (Active)##OTHER##;Tested and Approved##OTHER##;CPR##OTHER##;ATEX Classification##OTHER##;Model##OTHER##;Manufacturer##OTHER##;Type Comments##OTHER##;URL##OTHER##;Omniclass Code##OTHER##;Omniclass Description##OTHER##;Uniclass 2015 Code##OTHER##;Uniclass 2015 Description##OTHER##;Uniformat 2010 Code##OTHER##;Uniformat 2010 Description##OTHER##;Version##OTHER## 6295;Enclosed conventional heat detector 6295;100;75;82g;Ø 0.6 mm (0.3 mm²);Ø 1.2 mm (1.13 mm²);Polycarbonate_Panasonic_Grey;12 – 30 VDC;24 VDC (Zone Line);-40 to +50 °C;-45 to +70 °C;Maximum 95 % RH ;IP67;0 mA ;35 mA;EN54-5;2531-CPR-232.1192;"II 3 G Ex ic IIC T5 Gc X, II 3 D Ex ic IIIC T100°C Dc X -40°C ? Ta ? 50°C / EN IEC 60079-0:2018, EN 60079-11:2012";6295;Panasonic;6295 is a conventional fixed temperature heat detector. The detector will give an alarm at a certain fixed temperature (57 °C). The detector is intended for outdoor use or indoor use in high humidity premises;https://www.panasonic-fire-security.com;23.85.30.21.11.11.11;Smoke Detectors;Pr_75_80_30_27 ;Fire and smoke detector bases;D7050;Detection and Alarm;RVT20 6296;Enclosed conventional heat detector 6296;100;75;82g;Ø 0.6 mm (0.3 mm²);Ø 1.2 mm (1.13 mm²);Polycarbonate_Panasonic_Grey;12 – 30 VDC;24 VDC (Zone Line);-40 to +65 °C;-45 to +70 °C;Maximum 95 % RH ;IP67;0 mA ;35 mA;EN54-5;2531-CPR-232.1193;"II 3 G Ex ic IIC T5 Gc X, II 3 D Ex ic IIIC T100°C Dc X -40°C ? Ta ? 50°C / EN IEC 60079-0:2018, EN 60079-11:2012";6296;Panasonic;6296 is a conventional fixed temperature heat detector. The detector will give an alarm at a certain fixed temperature (72 °C). The detector is intended for outdoor use or indoor use in high humidity premises;https://www.panasonic-fire-security.com;23.85.30.21.11.11.11;Smoke Detectors;Pr_75_80_30_27 ;Fire and smoke detector bases;D7050;Detection and Alarm;RVT20 6297;Enclosed conventional heat detector 6297;100;75;82g;Ø 0.6 mm (0.3 mm²);Ø 1.2 mm (1.13 mm²);Polycarbonate_Panasonic_Grey;12 – 30 VDC;24 VDC (Zone Line);-40 to +80 °C;-45 to +70 °C;Maximum 95 % RH ;IP67;0 mA ;35 mA;EN54-5;2531-CPR-232.1194;-;6297;Panasonic;6297 is a conventional fixed temperature heat detector. The detector will give an alarm at a certain fixed temperature (87 °C). The detector is intended for outdoor use or indoor use in high humidity premises;https://www.panasonic-fire-security.com;23.85.30.21.11.11.11;Smoke Detectors;Pr_75_80_30_27 ;Fire and smoke detector bases;D7050;Detection and Alarm;RVT20 6298;Enclosed conventional heat detector 6298;100;75;82g;Ø 0.6 mm (0.3 mm²);Ø 1.2 mm (1.13 mm²);Polycarbonate_Panasonic_Grey;12 – 30 VDC;24 VDC (Zone Line);-40 to +110 °C;-45 to +70 °C;Maximum 95 % RH ;IP67;0 mA ;25 mA;EN54-5;2531-CPR-232.1195;-;6298;Panasonic;6298 is a conventional fixed temperature heat detector. The detector will give an alarm at a certain fixed temperature (117 °C). The detector is intended for outdoor use or indoor use in high humidity premises;https://www.panasonic-fire-security.com;23.85.30.21.11.11.11;Smoke Detectors;Pr_75_80_30_27 ;Fire and smoke detector bases;D7050;Detection and Alarm;RVT20